When is a balancing valve required in a Series Progressive system?
A balancing valve is used when pressure differences between lube points or between two secondaries are in excess of 1000 PSI. The valves are adjustable and provide back pressure which brings the pressure differences closer together ensuring that the divider outputs will equal their nominal rating(s).