When downloading a profile that contains a Start step Synergy Manager generates a “Profile invalid step type” error. Why?
A. Synergy Manager profile compiler does not support the Start step (Auto Start). When using Synergy Manager profile editor refrain from using the start step. As work around, put an extra ramp step at step 1 of the profile that sets dummy values. After profile download to the controller, manually change step 1 to a Start step with the appropriate values using the controller’s profile editor. The Start (Auto Start) step has been implemented for the VT3, VT4, VT5, and WF4 controllers in version 2.10.80 and later. Please refer to Synergy Manager User Manual for details.