Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What alternative method is available for existing stacks that cannot meet AS 4323.1-1995?

0
Posted

What alternative method is available for existing stacks that cannot meet AS 4323.1-1995?

0

It has been recognised that many existing industrial stacks have been constructed so that the location criteria in AS 4323.1-1995 cannot be met. To acknowledge this, AMSAAP specifies approved circumstances in which USEPA Method 1 can be used as an alternative method for determining a sampling plane location. In particular, USEPA Method 1 provides for sampling in a location that is sufficiently close to a flow disturbance that it would be considered non-compliant with AS 4323.1-1995. However, using USEPA Method 1 sampling at such a location is acceptable only if, it can be demonstrated that certain gas flow criteria outlined in the method can be achieved.