Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why is an additional power venter needed if the furnace already has an inducer?

0
Posted

Why is an additional power venter needed if the furnace already has an inducer?

0

The inducers in the furnaces have a distance limitation that would prevent them from venting safely from various locations. Also with the elimination of the HTPV (High Temperature Plastic Venting) systems the power venter is a safer and more efficient way of venting the furnace. Keeping the venting system under a negative pressure causes less worry of cracks. If one does occur, it would draw air into the venting system, not leak it out like a positive pressure system would.