Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why Frequency Domain Analysis?

analysis domain Frequency
0
Posted

Why Frequency Domain Analysis?

0

The analysis in the time domain is relatively simple to interpret and assesses the location of major defects. The analysis in the Frequency Domain computes the relative mobility and dynamic stiffness of the pile. Coupled with the Multiple Column plot, it allows the comparison of records from various piles from the same location. Dynamic stiffness yields a relative assessment of pile strength and quality. The Pile Profile Analysis generates a plot of pile impedance as a function of depth for piles with a clear toe.