Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why don HC49S and surface mount crystals pull as much as HC49U crystals?

crystals hc49s hc49u Mount pull
0
Posted

Why don HC49S and surface mount crystals pull as much as HC49U crystals?

0

The HC49U crystal utilizes a circular AT-cut crystal blank. Due to their small size, most surface mount crystals use a rectangular AT-strip cut crystal blank. (“Strip” refers to the rectangular shape of the blank.) While both are AT-cut blanks, several differences exist due to their different geometries. In general, given the same frequency and overtone, an AT-strip cut will have a lower Shunt Capacitance (CO) and Motional Capacitance (C1) than the AT-cut. Because pullability is a function of the capacitance ratio CO/C1, AT-strip crystals have less pullability. 19.