Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why does the DS3 card not report Alarm Indication Signal-Path (AIS-P) alarms from external equipment?

0
10 Posted

Why does the DS3 card not report Alarm Indication Signal-Path (AIS-P) alarms from external equipment?

0
10

A. The DS3 card terminates the signal on the ports at the backplane. To check the Performance Monitoring (PM) data on a DS3 from an external device, check the PM data on the OCn that is cross-connected to the DS3 circuit. This enables you to monitor any path-level errors that come in on the DS3 signal.