Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why do I get “unable to solve network hydraulic equations” or “network unbalanced”, when computing a model with several air valves?

0
Posted

Why do I get “unable to solve network hydraulic equations” or “network unbalanced”, when computing a model with several air valves?

0

Because air valves have the possibility to switch status, they can lead to instability in the model especially if there are many air valves in the system. To improve the stability of the model, it is desirable to force some of the valves closed. This can be done by setting the property “Treat air valve as junction” to True for those valves that are expected to be closed anyway.