Why do Hydraulic Systems Overheat?
Heating of hydraulic fluid in operation is caused by inefficiencies. Inefficiencies result in losses of input power, which are converted to heat. A hydraulic system’s heat load is equal to the total power lost (PL) through inefficiencies and can be expressed as: PLtotal = PLpump + PLvalves + PLplumbing + PLactuators If the total input power lost to heat is greater than the heat dissipated, the hydraulic system will eventually overheat. Installed cooling capacity typically ranges between 25 and 40 percent of input power, depending on the type of hydraulic system. Hydraulic Fluid Temperature How hot is too hot? Hydraulic fluid temperatures above 180°F (82°C) damage most seal compounds and accelerate degradation of the oil. While the operation of any hydraulic system at temperatures above 180°F should be avoided, fluid temperature is too high when viscosity falls below the optimum value for the hydraulic system’s components. This can occur well below 180°F, depending on the fluid’s viscos
Related Questions
- I hear radiant heating systems are slow to react, the so-called lag-period and also tend to overheat. Is system design a factor in these cases?
- I hear radiant heating systems are slow to react, the so-called lag-period and also tend to overheat. Is system design a factor in these cases?
- We have been offered other cover systems that have a hydraulic drive system, what is the difference?
- What components are powered by L, C and R hydraulic systems?
- What components are powered by L, C and R hydraulic systems?
- Why do Hydraulic Systems Overheat?