Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why do forward/redirect calls from the phone attached to the analog port of the ATA186 not work, but it is able to place and receive calls?

0
Posted

Why do forward/redirect calls from the phone attached to the analog port of the ATA186 not work, but it is able to place and receive calls?

0

A. This is because you cannot forward/redirect calls. The assumption is that you have configured the ATA 186 as an H.323 gateway in CallManager. Cisco recommends that you configure it as a dual-line H.323 client in order to have this functionality. Alternatively, you can download and use ata186-v2-12-ms-1129b-1.zip v2.12 software for SCCP and MGCP from CCO. This image allows you to use the ATA 186 as an MGCP/Skinny gateway.

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123