Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why do floors need to be reinforced when equipped with a ramp?

equipped floors Ramp reinforced
0
Posted

Why do floors need to be reinforced when equipped with a ramp?

0

Doors and floors are the most used and abused parts of a walk in cooler or freezer. Standard floors are designed with a 600-LB load per square foot. That sounds like a lot of load carrying ability until it is considered that a 200-LB load on a two-wheel cart can develop a load of 50-lbs per square inch or 7,200-lbs per square foot. Usually when a ramp is requested, it is assumed that two-wheel carts carrying heavy loads will be used in the walk in. Due to this factor, U.S. Cooler will only provide ramps with reinforced floors.