Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why Cannot Bind the Bypass Tunnel to the Active Tunnel?

active bind bypass tunnel
0
Posted

Why Cannot Bind the Bypass Tunnel to the Active Tunnel?

0

The possible causes can be: l The Bypass tunnel and Active tunnel use the same link. l If the main tunnel is configured with the bandwidth while the Bypass tunnel is not or the bandwidth of the Bypass tunnel is smaller than that of the main tunnel, the binding fails. l In addition, the Bypass tunnel provides the main tunnel with FRR protection, including link protection and node protection. The protection can cover only a maximum of one node; otherwise, the binding fails and the following display prompts: Error: CheckBypass path failed as number of Hops Bypassed exceeds threshold.