Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why are some tendons shown at the wrong elevation in the tendon perspective?

0
Posted

Why are some tendons shown at the wrong elevation in the tendon perspective?

0

The soffit elevation at each profile point is determined during the Analyze All and Calculate All commands. If one of these commands is not performed since the drawing (or moving, etc.) of a tendon, or since a change in the mesh, the tendon elevations in perspectives are not accurate. The same is true for elevations optionally shown as text on the plans. It is quicker to analyze (but not using “Calculate All”) with Process > Analyze All. This avoids processing the design calculations.