Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Why are some interfaces labeled as IfIndex2,IfIndex3, etc.?

0
10 Posted

Why are some interfaces labeled as IfIndex2,IfIndex3, etc.?

0
10

This happens if the device/interface has not responded to the SNMP requests sent by NetFlow Analyzer. Check the SNMP settings of the interface or manually edit the interface name from the Dashboard. NetFlow Analyzer uses port 161, and the public community string as default SNMP values. If the SNMP settings of your device are different, change the vaues in the Dashboard Interface View. If you need to change this globally, enter the new values in the same fields under Settings.