Which Stratix® series devices support a slew rate option?
Solution For Stratix and Stratix GX devices, the “slow slew rate” option is available in the Assignment Editor of Quartus® II software. The assignment value choices are on or off. For Stratix II and Stratix II GX devices, the “slow slew rate” option is not available. For Stratix III devices, the programmable “slew rate” option is available in the Assignment Editor of Quartus II software. Quartus II allows four settings for programmable slew rate control—0, 1, 2, and 3—where 0 is slow slew rate and 3 is fast slew rate.