Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

Where is the voltage setpoint measured on a configured Xgen?

0
Posted

Where is the voltage setpoint measured on a configured Xgen?

0

For powerMods Xg1 to Xg5 the output voltage is set at the positive and negative sense pins, i.e. Pin1 and Pin 2 of Connector J3. For powerMod Xg7 the output is set at the +Vout (Pin2) and -Vout (Pin 1) of the J4 connector. For powerMod Xg8 the output is set on the +Vout and -Vout pins for each output, i.e. Pin 4 through to Pin1 respectively of the connector J4.