Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

When viewing a particular PVC view from within the Troubleshooting Toolset, the following message is generated: Cannot contact the far side ASE. Why?

0
Posted

When viewing a particular PVC view from within the Troubleshooting Toolset, the following message is generated: Cannot contact the far side ASE. Why?

0

A. This typically is the result of an incorrect DLCI association and incorrectly mapped PVC. Verify the PVC mapping information you configured is correct. Do this by performing a Traffic Capture on each end of the circuit and validating the DLCI numbers used at each end.