Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

When the OPT-24 card is installed, is it possible to leave the other (back-plane, card cage) cards installed and active?

0
Posted

When the OPT-24 card is installed, is it possible to leave the other (back-plane, card cage) cards installed and active?

0

The OPT-24 is a 24-channel I/O card that uses the ADAT TM fiber optic (lightpipe) interface. Unlike the standard I/O cards, it is installed in the ACC1 (ACC on the MDR) PCI slot, interfacing directly with the Mother Board. When installed, the OPT-24 card appears in the Digital I/O Setup menu as three 8-channel I/O devices. Each bank of eight inputs can be selected between the OPT-24 and whatever card is installed in that bank’s I/O card cage slot. Outputs of the OPT-24 (as well as cards installed the I/O card cage) are active all the time, so there’s no output selection.