Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

When testing the D-60A , the +5V channel is correct, but the +12V channel is over the specification. What is going on?

0
Posted

When testing the D-60A , the +5V channel is correct, but the +12V channel is over the specification. What is going on?

0

There are some minimum-load requirements on Mean Well’s multi-output power supplies, please refer to the specification first before connecting the load. When the load condition is 5V/ 4A , 12V/ 0A , the output voltage of the 12V channel will be around 12.8V that is over the 6% of voltage deviation (12.72V) specified in the spec. sheet. If we add in the minimum load 0.2A to the 12V channel, the 12V channel will reduce to around 12.3V which is within the specification.

What is your question?