Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

When on the Setup screen I cannot change the communications port or select TCP/IP as the communications device. What is wrong?

0
10 Posted

When on the Setup screen I cannot change the communications port or select TCP/IP as the communications device. What is wrong?

0
10

The EM615-G software will not let you select a device which does not exist or use a device driver unless it is currently loaded on your system. If trying to select a different serial port, verify that the port is enabled in your computer s setup and the serial port is set to a standard address (i.e.: COM1, COM2). If trying to select TCP/IP for a network connection, verify that your TCP/IP kernel (Sockets) is loaded. From a DOS prompt, run your network version of PING and make sure a host can respond to your system. If trying to use TCP/IP, make certain the EM615-G software you are using is configured for your network type. When the EM615-G Welcome screen is displayed, the top box with the software credits will display WOL for Wollongong; NOV for Novel LWP; FTP for FTP s kernel and; LM for Microsoft s LAN Manager using Sockets.