Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

When importing data into PHREEQC, one or more parameters are not added. How can these be added in AquaChem v5.1?

0
Posted

When importing data into PHREEQC, one or more parameters are not added. How can these be added in AquaChem v5.1?

0

In order to write a parameter value to the PHREEQC output file, AquaChem v5.1 must know which database parameter corresponds to the PHREEQC master species parameter. This is defined within the thermodynamic database (i.e. phreeqc.dat). If a master species can be mapped to a AquaChem parameter, then the AquaChem parameter name has to be added at the end of the line as a comment (#parameter name). If one or more parameters has not being added, the link to the parameter is likely missing. Please open the phreeqc.dat file, or the thermodynamic database you are using and add #[parametername] in AquaChem at the end of the line. Start AquaChem again using the phreeqc.dat file in the following format.

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.