Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

When doing P-Delta analysis for the design, what does the message “Load Case = 101 Convergence Error (SRSS) = 3.6603E-02 INCH” in the output file mean?

0
Posted

When doing P-Delta analysis for the design, what does the message “Load Case = 101 Convergence Error (SRSS) = 3.6603E-02 INCH” in the output file mean?

0

“Load Case = 101 Convergence Error (SRSS) = 3.6603E-02 INCH” is NOT an error message. It is a measure of the convergence tolerance. If are getting a lot of these messages and you don’t want to see so many of them you can set your tolerance to a lower value, say, 1/4 “. This can be done by adding “SET DISP 0.25” into the std file, provided the units has been set to inches.