When attempting to create an isometric, using the Isogen export facility, an error stating “Piping Model Creation Failed” is displayed. What is wrong?
The installation of the software attempted to register pipedll.dll with Windows. This registration process failed because access to a valid ESL is required (which isn”t available at during the installation of Version 5.00). To correct this problem register this DLL manually. There are two ways to accomplish this registration: 1) Using Windows Explorer, navigate to the CAESAR II program directory, find the file netuserC2.bat and double click it, or 2) Use the [Start\Run] box and issue the command “regsvr32 “c:\program files\coade inc\caesar ii 5.00\pipedll.dll”. This path may be different if you installed CAESAR II to a different location. Note, both options assume you have the necessary rights to register a DLL. If this is not the case, you will need assistance from your IT Department.
Related Questions
- When attempting to create an isometric, using the Isogen export facility, an error stating "Unexpected error creating isometric, Directory Access is denied" is displayed. What is wrong?
- When attempting to create an isometric, using the Isogen export facility, an error stating "Pure Virtual Function Call" is displayed. What is wrong?
- When I try to create an isometric using the Isogen export facility, I receive an error stating "Piping Model Creation Failed." What should I do?