When and how does nonstructural mechanical prosthetic heart valve dysfunction occur?
OBJECTIVE: We discuss the clinical aspects related to mechanical valve dysfunction based upon 20 years’ experience of our cases. METHODS: Between January 1982 and December 2001, 21 patients underwent surgical interventions because of mechanical valve dysfunction. Thirteen men and 8 women (mean age 47 +/- 20, range 3-75 years-old), were included. RESULTS: Mitral valve dysfunction was observed in 12 patients. Prosthetic valve stenosis occurred in 6 patients between 2 and 224 months, and paravalvular leaks in 4 between 1 and 71 months after surgery. The other 2 patients suffered from hemolytic anemia with mild paravalvular leaks between 102 and 104 months after surgery. Aortic valve dysfunction was observed in 8 patients including 3 stenotic lesions between 48 and 97 months and 5 paravalvular leaks between 3 and 150 months after surgery. Tricuspid regurgitation was seen in 1 patient with a huge right atrium at 42 months after surgery. Early death was seen in 1 patient. Late death occurred