Whats the reason judgement method and solution for the unsuccessful main control switch configuration on network management DeviceMaster of Switch, or can not renovate interface?
1, When adding node, the input visiting group name is not consistent with the read-only and read-write group names. On switch use show snmp-server to examine visiting group name, on DeviceMaster, use the right key menu at the node to examine the attribute visiting group name, and compare whether the input group name on network management is consistent with that on the switch. If the group name is consistent with read-only, then only can carry on renovating to examine operation, cannot configure. If it’s consistent with read-write, then can both renovate and configure. 2, Solution: make sure that the visiting group name on the DeviceMaster is consistent with that on the switch.