What water pressures and temperatures will the mixing valve operate under?
A. As with most mixing valves nominally equal hot and cold pressures are recommended. Rada Acu mixing valves are rated to a maximum static inlet pressure of 10 bar (1000kPa) and minimum static pressure of 1 bar (10okPa) and require at least 0.2 bar (20kPa) minimum pressure loss to operate. Cold inlet temperatures can be between 1 and 20 ºC, and hot water inlet temperatures can be between 50 and 65ºC. For further details please see our full Specification sheets.