Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What types of boundary conditions does SUTRA support?

0
10 Posted

What types of boundary conditions does SUTRA support?

0

SUTRA supports the following four types of boundary conditions, all of which are specified at nodes: fluid sources or sinks (dataset 17); solute mass or energy sources or sinks (dataset 18); specified pressures (dataset 19); and specified solute concentrations or temperatures (dataset 20). Boundary conditions are not restricted to nodes at the physical boundary of the model; they can be specified at any node. By default, there is no flux of mass or energy in or out of the model domain at any node for which a boundary condition is not explicitly specified.