What should I do if I have intermittent or non-operating DA-057 Powerflash Interface and DA-058 Chime modules (X-10)?
When using the DA-500 and DA-057 Powerflash Interface transmitter and DA-058 Chime module, verify you have a correct hookup (including all DA-057 and DA-058 switch settings). If it’s a new hookup, also verify correct wiring is in use, (resistor network to lower control voltage to DA-057 approximately to 12-13VDC and wiring is correct). x10If it’s an existing hookup that has been working properly, verify the Drive Monitor control panel is functioning correctly. Then press the Powerflash Interface transmitter TEST button (upper left) to activate the remote chime. If there is no response, move the chime to the same location as the DA-057 transmitter and check once more. Verify the house and unit code settings are the same on each module. If there is no response, then either one or the other module is defective and needs replacement. If the modules work at the same location, then try another outlet in the chimes’ location. Also see suggestions for using a Passive Phase Coupler under the fo