Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What power components were included in our 50 mgd NPV model?

0
Posted

What power components were included in our 50 mgd NPV model?

0

The NPV model used estimated allowances for the total treatment power including raw seawater intake pumps (200 ft-head), pre-filtration pumps (105 ft-head), the actual RO process number from the ADC pilot, product water lift pumps (40 ft-head) and product water finish pumps (200 ft-head). For the first set of SW30HR-380 membranes, the total treatment power from our NPV model at the MAP was 10.67 kWh/kgal (2.82 kWh/m3) verses 7.15 kWh/kgal (1.89 kWh/m3) for the RO process alone.