Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the update cycle for the D/A output of the WE7141 100 MHz Universal counter module?

0
Posted

What is the update cycle for the D/A output of the WE7141 100 MHz Universal counter module?

0

The update cycle changes depending on the acquisition mode and the gate time during frequency measurement. When the acquisition mode is [One Shot], the update cycle is approximately 0.5-1 seconds. However for frequency measurement, it’s about 10 seconds when the gate time is 10 seconds. When the method is [Free Run], the update cycle occurs at each sampling interval. However for frequency measurement, it occurs approximately at each (gate time + sampling interval).