Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the tolerance on depth for built-up girders and trusses?

0
Posted

What is the tolerance on depth for built-up girders and trusses?

0

The appropriate tolerances for the welded cross-section are specified in AWS D1.1-2004 Section 5.23. However, at bolted splices for such members, AWS D1.1-2004 Section 5.23 is silent on this subject. AISC recommends that the permissible deviations for girder depth in AWS D1.1-2004 Section 5.23.9 be applied to depth at bolted splices. Any differences within the prescribed tolerances at such joints should be taken up, if necessary, by shimming.