Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the recommended supply voltage for the MCAS controller?

0
Posted

What is the recommended supply voltage for the MCAS controller?

0

The controller will accept a voltage range of 7.5 to 25VDC. However, if you plan to implement a door-activation device, your supply voltage must match the coil voltage of the activation relay. Our field wiring terminal board (FWTB) includes an activation relay with a coil voltage of 12VDC. Therefore, 12VDC is recommended if you use the FWTB.