What is the PWM frequency under (6+2) mode and (7+1) mode?
Answer For PWM (6+2) mode, the PWM cycle is divided into 4 modulation cycles. Each modulation cycle has 64 PWM input clock periods, and the PWM frequency will be fSYS/26. For PWM (7+1) mode, the PWM cycle is divided into 2 modulation cycles. Each modulation cycle has 128 PWM input clock periods, and the PWM frequency will be fSYS/27. In comparison with the 8-bit mode, the (6+2) Mode PWM frequency is 4 times higher and (7+1) mode is 2 times higher than that of the 8-bit mode.