Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the purpose of the signal contact on the safety valve MS6-SV?

0
Posted

What is the purpose of the signal contact on the safety valve MS6-SV?

0

The signal contact on the safety valve MS6-SV is designed to signal whether the valve is ready to be switched on, i.e. the valve runs a self-test after switching on. If everything is in order, the signal contact switches to the high state. The valve with two enable inputs can now be switched on. The signal contact can be connected into the feedback loop of a safety control system.

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.