What is the primary difference between the Standard (-100) and High Performance (-101) versions of the Model QRS11?
Both QRS11 versions are the same basic high reliability Quartz Sensing Element. The primary difference between the “standard” performance and the “high performance” versions is the maximum possible change in bias offset (DC) over the operating temperature range. For example, the bias offset of a Standard version of a Model QRS11 with a full scale range of ±100°/second could change by up to 1.8°/second over the operating temperature range. For the High Performance version, the maximum possible change would be <=0.35°/second. Actual QRS11 performance, for either version, is typically well within the foregoing limits.