Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the Paragon II Hub-Pac Power up Sequence?

hub-pac ii Paragon power sequence
0
Posted

What is the Paragon II Hub-Pac Power up Sequence?

0

• All devices and targets must be powered off • Connect CIMs to targets • Connect CIMs to Hub-Pac • Configure Hub-Pac to PII UMT (make topology connections with all devices off) • Power up Targets • Power up Hub-Pac (Power on one PII Hub-Pac at a time). • Execute the 1st to 3rd tier power sequence with a partial reset on base after the system database has been loaded. If multiple base units are involved, execute partial reset on each base after the data base is loaded. The database is not completed loading if the LCD of the base UMT flashes “DB Sorting…” message.

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.