Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the operating voltage from the drive control board to the SQUIGGLE motor?

0
Posted

What is the operating voltage from the drive control board to the SQUIGGLE motor?

0

• The SQL-1.8 motor (with direct drive) operates at up to 40 volts peak to peak. • The SQL-3.4 motor (with resonant drive) operates between 50 and 100 volts peak to peak. • The SQ-100 series motors (with resonant drive) operate between 75 and 150 volts peak to peak.

0

• The SQL-RV-1.8 motor (with direct drive) operates at 2.3 to 11 volts peak to peak. • The SQL-3.4 motor (with resonant drive) operates between 50 and 100 volts peak to peak. • The SQ-100 series motors (with resonant drive) operate between 75 and 150 volts peak to peak.