Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the most expedient method for sterilizing a heat sensitive liquid that contains spore-forming bacteria?

0
Posted

What is the most expedient method for sterilizing a heat sensitive liquid that contains spore-forming bacteria?

0

For sterilizing a heat sensitive liquid, it needs to be filtered through membrane filter having pore size 0.22micron. These are nitrocellulose membranes available with Milli pore company. These membranes are available in different diameters. These need to be put in a special assembly which can be autoclaved after fitting the membrane inside the assembly. One has to decide about the suitable assembly depending upon the volume of the liquid. If you want to filter 20 to 50 ml of liquid, then a small assembly can be conveniently used with a syringe attached to it. The filtration needs to ba carried out in sterile area preferably a laminar cabinet. The filtrate needs to be collected in a sterile container.