What is the maximum pulling tension and minimum bending radius of outside plant cables?
Cable tensile load ratings, also called cable pulling tensions or pulling forces, are specified under short term and long term conditions. The short-term condition represents a cable during installation and it is not recommended that this tension be exceeded. The long-term condition represents an installed cable subjected to a permanent load for the life of the cable. Superior Essex’s loose tube cable designs have a short term (during installation) tensile rating of 600 pounds (2700 N) and a long term (post installation) tensile rating of 200 pounds (890 N).