What is the maximum number of boxes on a Soundweb network?
This will depend on system design and complexity. In practice, you are likely to be limited by the speed of Soundweb Designer, which will gradually slow down as the system gets very large, or by the distance limits mentioned above. Currently, we have tested single-network systems without 9000ii hubs (a single daisy-chain of 9088’s, up to a maxium of 25 units (whether these are 9088 or 9010 remote devices or mixed). Larger networks using 9000ii hubs have been tested to 100 units (mixed 9000ii, 9088 and 9010 devices), and therefore it is recom-mended that this number should be used as a limit for single network systems. If you anticipate using more than this, please contact BSS Audio prior to finalising a system design.