Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the maximum duration for a 1 or 0 before the dataslicer threshold point drifts away?

0
Posted

What is the maximum duration for a 1 or 0 before the dataslicer threshold point drifts away?

0

One strength and big advantage of our ATR2406 compared to competing products is that there is no analog dataslicer inside, it is a purely digital demodulator. So, there is no drift nor are there restrictions on sync word length and data message in real applications. The maximum transmit slot length is determined by the loop filter time constant. For more details please see the application note ATR2406 Loop Filter and Data Rates.

Related Questions

What is your question?

*Sadly, we had to bring back ads too. Hopefully more targeted.

Experts123