What is the maximum allowable cycle time for garage doors?
If the surface area of the garage door is less than 75 sf, then the maximum allowable cycle time is 3 seconds. If the surface area of the garage door is greater than 75 sf, then the maximum allowable cycle time, in seconds, is determined by the following equation: (Area of garage door – 75) x F-3. Where F=0.6 for sectional doors and F=0.35 for roll-up doors.