Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the in-plane shear capacity of the countersunk 5/8″ diameter bolts on the double 2x beam top nailer?

0
Posted

What is the in-plane shear capacity of the countersunk 5/8″ diameter bolts on the double 2x beam top nailer?

0

This connection was tested and found to be slightly lower than a calculated value. The ASD capacity is 2000 lbs per bolt with no increase permitted for load duration. The 9-inch-deep beams have 10 bolts total along the length of the top nailer whereas the 12-inch-deep beams have 14 bolts total.