What is the best way to change the DM24 and SAM baud rates?
A. If you change the SAM baud rate before the sensor, you will no longer be able to communicate with the sensor. Open a terminal on the sensor icon, then execute the following string of commands: 0 19200 baud; go; 1 19200 baud; 2 19200 baud; 0 19200 baud; go. This will then close the terminal. Delete the SAM/DM24 icons from Scream and wait for them to reappear (set the scream com port to Auto-detect baud rate). If all else fails, go to the DM24 direct via the data terminal with a dual power-serial cable attached to a battery.