Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What is the accuracy of clinic blood pressure measurement?

0
Posted

What is the accuracy of clinic blood pressure measurement?

0

GROUND: In clinical practice, blood pressure (BP) is frequently measured at the end of the visit in patients sitting on one side of the bed and not on a chair according to guidelines. METHODS: In 540 consecutive subjects with essential hypertension (EH) attending a hospital outpatient clinic, BP was measured in the following sequence: 1) patient seated on chair for at least 5 min, 2) patient supine, 3) patient seated on bed, and 4) patient standing for a few minutes. RESULTS: We found that mean (+/-SEM) BP was 143.5/87.2 +/- 0.9/0.5, 153.4/89.7 +/- 1.0/0.5, 148.9/90.9 +/- 1.0/0.5, and 144.8/91.7 +/- 1.0/0.6 mm Hg, respectively (P < .05 v position 1 for all). In 14% of patients, either systolic BP (SBP) or diastolic BP (DBP) was above the conventional upper limits of normality in the seated-on-bed but not in the recommended seated-on-chair position ("false" high clinic BP), whereas SBP and DBP were "false" normal (below limit for bed-seated and above limit for chair-seated position) in