Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What if the void between the floor slab and the perimeter curtain wall is a width greater than the recommended 2″ to 8″?

0
Posted

What if the void between the floor slab and the perimeter curtain wall is a width greater than the recommended 2″ to 8″?

0

The standard safe-off area width Thermafiber has evaluated through fire tests with standard 3″ impaling safing clips is 8″. For greater gap widths (up to 12″), Thermafiber provides recommended installation methods for protecting wider safe-off openings.