Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What has to be noted if the dialer is connected between the NT and the comity® – server?

connected Dialer noted NT server
0
10 Posted

What has to be noted if the dialer is connected between the NT and the comity® – server?

0
10

Because the NT has more than one call numbers the dialer and the ISDN card should have different call numbers. MAMS has to be configured as well with a different number. Therefore make a connection to MAMS. Then press with the right mouse button the connection icon for opening the menu. Over Properties -> Connection, then enter in the Destination – field the following: For versions from comity® 2.3 or MAMS 1.37f type: /n=X /m=Y For the earlier versions of comity® or MAMS: X Y Here indicates X the number which is the receive call number of MAMS, and Y the own number of MAMS, which will be send from MAMS. Both numbers must be only local numbers without the prefix. Example: C:\\comity\\config\\MAMS.