What goes wrong with gas regulators on LP Gas Tanks?
Gas pressure too high: Adjustment of a gas regulator might also be necessary if the gas piping from source (meter or tank) to the appliance is long or is too small in diameter. If the gas regulator delivers gas at too high a pressure the gas flame may be also too big (and too hot), which can accelerate rusting and can warp the heat exchanger at its lower joints causing a “crack” to appear. A cracked heat exchanger on a gas appliance is unsafe. Our correspondent, Charles commented that: After loosing three heat exchangers in two different homes that had routine maintenance inspections, I decided to look into it and check the gas regulator pressure myself. The same problem can occur with gas water heaters. Gas pressure too low: if the gas regulator is not properly adjusted or if there are other problems in the gas piping or supply system the gas pressure may be too low, providing an inadequate and possibly unsafe flame. Depending on the cause of the problem, it may be possible to correct