Important Notice: Our web hosting provider recently started charging us for additional visits, which was unexpected. In response, we're seeking donations. Depending on the situation, we may explore different monetization options for our Community and Expert Contributors. It's crucial to provide more returns for their expertise and offer more Expert Validated Answers or AI Validated Answers. Learn more about our hosting issue here.

What does the E0CF5 Log Disable SBE message on the LCD of my PowerEdge 2650 server mean?

0
Posted

What does the E0CF5 Log Disable SBE message on the LCD of my PowerEdge 2650 server mean?

0

This message indicates multiple single-bit errors on a single memory module. Most errors of this sort are the result of poor connections. Shutdown the server and reseat the DIMMs on the motherboard. If the problems continue, update the System BIOS, ESM firmware and ERA firmware to the latest version.