What detailing is required for a typical lagging wall with DMX Drain 6000?
For straight forward lagging wall installation the main details to watch for at the interface of the DMX Drain 6000 are the post tensioned cable points, seam overlaps of the Drainage Geocomposite, taping of the seams in the DMX Drain 6000, wrapping of geotextile over the top of the plastic core, attachment of the DMX Drain 6000 to the structural substrate, discharge of collected water at the bottom of the DMX Drain 6000. These details are covered in our Installation Manual and as downloads in DWG or PDF drawings on our web site. These details are the most important ones to remember.